Application

Kestopur PL 100/20 is a fast-curing, fire classified, one-component polyurethane adhesive. Builds some amount of foam while curing. Kestopur PL adhesives are fire classified according to IMO FTPC (IMO Resolution MSC.61(67) Part 5) and have an MED certificate (Wheelmark). Kestopur PL 100/20 is used for the gluing of wood, steel, aluminium, various insulation materials and plastics. Retains its elasticity also at low temperatures.

Package Size Product Code
Kestopur PL 100/20 15 kg/ 10 l T1158.010
Kestopur PL 100/20 300 kg/200 l T1158.200
Kestopur PL 100/20 Schütz cont T1158.996
Density/specific weight

Approx. 1.50 kg/dm³

Colors

light

Lap shear strength

- SS–SS 5 N/mm²
- epoxy coated sheet metal 12 N/mm²
- common beech/common beech 8.8 N/mm²
- EN 204–D4 storage sequence 5.0-6.0 N/mm

Viscosity

9 000 mPas (Brookfield, RVT 20 °C);

Open time

max. 30 min.

Consumption

200–400 g/m² depending on materials

Pressing time

6 h / 20 °C (water spray 20–30 g/m²)

Package sizes

10 l, 200 l, 1000 l

Storage

Unopened (+10–+20 °C) for 6 months. Note! During the summer months, when the weather is warmer and air humidity higher, the shelf-life can be significantly shorter, even 3 months. Max. storing temperature +30 °C.

Instructions for use

The surfaces to be bonded must be clean and dry. Remove oxidations, grease and other impurities using solvent or by sanding, depending on the case. Apply the adhesive in an even layer on one of the surfaces. A thin layer of water sprayed on the adhesive layer shortens the pressing time. Remove fresh adhesive stains with a dry cloth and clean the surfaces with acetone or xylene. Hardened adhesive can only be removed by mechanical means. We recommend using adhesive at room temperature. However, the gluing can be carried out at lower temperatures (even at +5–10°C), but then the curing time will be much longer.

Additional information

The information given in this product data sheet is based on our tests and our practical knowledge. The technical data is defined in standard conditions. Variations in local working conditions and methods will affect the product performance and result. The result is strongly affected by working methods. We guarantee the high quality of our products according to our Quality Management System. No liability can be accepted from incorrect use of the product or prevailing conditions, over which we have no control. Thus, we cannot be held responsible for the final result. The user of the product must test product’s suitability to the intended application.

Environment and safety

Avoid unnecessary skin contact with and exposure to the fresh product: use safety gloves. Refer to material safety data sheet. For information on product and package disposal, visit www.kiilto.com.